• H05V-R
  • H05V-R
  • H05V-R
  • H05V-R

H05V-R

These cables are mainly used for indoor, cable ducts and industrial plants or switching stations, underground installation. They can be used in switchboards and distribution boards or equipment requiring more wire strands. They are used for export to European countries in electronic machinery and switchgear, and can be used as an alternative to MRO of European-made equipment wires.
$0.00
Cable parameter:
TUV,CE
TUV,CE
CE
CE
  • H05V-R
  • H05V-R

Description

Application and Description

These cables are mainly used for indoor, cable ducts and industrial plants or switching stations, underground
installation. They can be used in switchboards and distribution boards or equipment requiring more wire strands.
They are used for export to European countries in electronic machinery and switchgear, and can be used as an
alternative to MRO of European-made equipment wires.
                                                                                                                                                                                               

Standards and certifications

HD 21.3 S3, BS 6004, VDE-0281 Part 3, CEI 20-20/3, CEI 20-35 (EN60332-1) CEI 20-52, CE Low Voltage
Directives 73/23/EEC and 93/68/EEC, ROHS certification
                                                                                                                                                                                               

Cable construction

- Solid/stranded bare copper conductor

- Comply with VDE-0295 Cl-2, IEC 60228 Cl-2

- PVC (polyvinyl chloride) TI1 insulation

- Color coding of cores complies with VDE-0293
                                                                                                                                                                                               

Technical characteristics

- Working voltage: 300/500 V(H05V-R), 450/750 V(H07V-R)

- Test voltage: 2000 V(H05V-R), 2500 V(H07V-R)

- Dynamic bending radius: 15 x Ø

- Static bending radius: 15 x Ø

- Operating temperature in application: -5º C to +70º C

- Flame retardant: IEC 60332.1

- Insulation resistance: 10 MΩ x km
                                                                                                                                                                                               

Cable parameters:

Number of cores x conductor cross-sectional area

# x mm²

Nominal insulation thickness mm

Nominal outer diameter mm

Nominal copper weight kg/km

Nominal cable weight kg/km

H05V-R

1 x 0.5

0.6

2.2

4.8

9

1 x 0.75

0.6

2.4

7.2

12

1 x 1

0.6

2.6

9.6

15